​ ​ ​ ​ ​ ​ ​ ​ HealthmateForever Powered Pulse Muscle Stimulator system PRO

NK10AB HealthmateForever TENS Unit & Muscle Stimulator

  • $ 109.99
  • Save $ 210.00


  • 1 Double Value 2in1 FDA cleared Class II OTC HealthmateForever NK10AB electroTherapy device (combined TENS unit and Muscle Stimulator)
  • 4 piece self-adhesive conductive reusable gel pads
  • 2 sets of electrode wires (3.5mm plug)
  • 1 USB Charger/Wall Unit (international travel charger 110V - 240V)
  • 1 pads holder
  • User Manual
  • Limited Lifetime Warranty Card
  • ATTENTION: Upgrade to Wireless Kit in drop down menu
  • If any questions or concern please feel free to contact us.
  • 10 preprogrammed massage modes with different waveforms:
    • Tuina (Push & Pull), Acupuncture, Tapping, Guasha (Scraping), Leg, Cupping, Body Building, Body Building2, Foot, and Combination
  • Adjustable 10-60 minute timer
  • 20 levels of adjustable intensity in channel A or channel B
  • Dual outputs are isolated, so both channel A and channel B has the same 100% power, without reducing strength in half
  • Allows 4 pads to be applied to the two different targeted areas at the same time
  • Rechargeable internal lithium battery – up to 10 hours of continuous use
  • Easy to read animated backlit LCD Display
  • If any questions or concern please feel free to contact us.
  • Output pulse width: 90μS ± 15%
  • Pulse Frequency: <100HZ
  • Max output amplitude: <5v (r.m.s)
  • 3.5mm plug
  • Screen size: 1.25" W x 1.5" L
  • Size: 1.5" L x 3" W x .5" T
  • Weight: 1.3oz
  • If any questions or concern please feel free to contact us.

    Step 1: Connect electrode wires with control unit.

    1. Plug the electrode wire into the device.
    2. Ensure that the electrode wires are fully inserted into the output and secured.
    3. Repeat steps 1 & 2 to connect another wire.

    Step 2: Connect electrode pads with wires.

    1. Each wire has two leads with snap-on connectors. Snap the wire connectors onto the snap on buttons on the pads.
    2. Make sure at least one pair of pads is attached to the same wire.
    3. Ensure that the snap on connections are fastened.
    4. Remove the plastic films on the pads.

    Step 3: Place pads on your body.

    Place pads on the muscle you would like to treat. Place the adhesive side of pad on your skin.

    Step 4: Turn on the control unit.

    Push the “ON/OFF” switch.

    Verify the channel indicator on the screen to make sure the device is on the same channel you wish to use. The “A” letter will blink to indicate channel A is working. The “B” letter will blink to indicate channel B is working. 

    Step 5: Select modes.

    1. You can see some different modes on the screen.
    2. The device will automatically set to channel A, mode 1 with zero intensity.
    3. “M” is mode changing button. Press “M” button to change mode and select the mode you want to use.
    4. Press the channel switch button once to switch from channel A to channel B. The B letter will blink to indicate channel B is working. Repeat the steps above.
    5. Press the “M” button to change cycle through modes. Keep pressing the “M” button to get to the desired mode.

    Step 6: Adjust timer.

    Press the “T” button to adjust timer.

    Step 7: Select intensity.

    Press the intensity “+”“-” button to set the desired intensity.

    Press intensity “+” button to increase the intensity.

    Press intensity “-” button to decrease the intensity.

    When switching modes, the intensity will automatically set zero. Repeat step 7 after changing the mode.

    As mentioned previously, this device is equipped with two isolated channels A&B. You will need to adjust the intensity for each channel separately by pressing the mode switch button.

    You have the option to use one channel alone or both channels.

    Step 8: Turn off the device.

    Push the “ON/OFF” switch.

    Step 9: Remove the pads from your skin.

    Remove the pads from your skin softly and place them back on the provided pad holder or the protective plastic film.

    DO NOT remove the pads before you turn off the device.

    Step 10: Take off the pads from wires. Unplug wires from device.