​ ​ ​ ​ ​ ​ ​ ​ Best TENS unit Electronic Pulse Massager | HealthmateForever

CT15AB HealthmateForever TENS Unit & Muscle Stimulator
Free Gift

  • $ 49.99


  • 1 FDA cleared Class II OTC HealthmateForever CT15AB electroTherapy device (combined TENS unit and Muscle Stimulator)
  • 8 piece self-adhesive conductive reusable electrode pads with inserted pin
  • 4 sets of inserted pin electrode wires (3.5mm plug)
  • 1 Pads holder
  • Warranty Card
  • User Manual
  • 3 AAA batteries

If any questions or concern please feel free to contact us.

  • 15 preprogrammed electronic pulse massager massage modes:
    • 9 custom designed modes: Neck, Shoulder, Back, Elbow, Hip, Ankle, Knee, Foot/hand, And Wrist; 
    • 6 therapeutic methods: Knead, Acupuncture, Tapping, Cupping, Scraping, and Random.
  • Default timer: 80 minutes. When time is due, it is automatically shut off.
  • 20 levels of adjustable intensity
  • 4 outputs design with independent intensity control in Channel C1/C2 or Channel C3/C4
  • Allows 8 pads to be used at the same time
  • Your electronic pulse massager uses 3 AAA batteries
  • Easy to read animated back-lit LCD Display
  • Belt Clip
  • Power saving with Auto shut off when the device is not used
  • If any questions or concern please feel free to contact us.

Electronic pulse massager Output Parameters:

  • Output pulse width: 90 μS ± 15%
  • Pulse Frequency: <100 HZ
  • Max output amplitude:  <5v (r.m.s)

Input Parameters:

  • Input voltage: DC5V
  • Rated current:   ≤ 50 mA
  • Rated power:  0.25 W 
  • Screen size: 1.75" W x 1" L
  • Size: 4" L x 2.5" W x .75" T
  • Weight: 4.6oz

If any questions or concern please feel free to contact us.

Step 1: Set up batteries.

  1. Check if the batteries are in good condition.
  2. Remove the battery cover located on the back of the device.
  3. Insert 3* AAA batteries. Make sure the “+” “-” sides correspond.
  4. Put the battery cover back.

Step 2: Connect electrode wires with control unit.

CT15AB has two independent channels with 4 outputs C1, C2, C3, and C4 combining C1&C2 on one channel, C3&C4 on the other channel. This will allow you to set separate levels of intensity on C1&C2 and/or C3&C4. Before connecting the wires with unit, decide which channels you wish to use.          

  1. Plug the electrode wire into the output(s) located at the top of the device. Depending on your needs, you may use one, two, three or four outputs.
  2. Ensure that the electrode wires are fully inserted and secured into the output.
  3. Repeat steps 1 & 2 to connect another wire.

Step 3: Connect electrode pads with wires.

  1. Each wire has two leads with pin-insert connectors. Plug the male pin-insert end on the wire into the female pin-insert connector on the pads.
  2. Make sure at least one pair of pads is attached to the same wire.
  3. Remove the plastic films on the pads.

Step 4: Place pads on your body.

Place the pads on the area you would like to treat. Place the adhesive side of pad on your skin.

Step 5: Turn on the control unit and select channel.

When looking at the unit directly, below screen on left hand side, open the key pad cover by pushing the cover upward with your left thumb.

Press the “ON/OFF” button located on the upper left corner of key board. The screen will light up and display all indicators.

Verify the channel indicator on the screen to make sure the device is on the same channel you want. If the “CH1 CH2” on the screen is blinking, you can change the setting of “CH1 CH2”. If “CH3 CH4” is blinking, you can change the setting of “CH3 CH4”. Please ensure wires are plugged into the correct outputs.

Step 6: Selecting modes.

You can select any of the 15 programs by pressing the “PRG” buttons. To go from program 1 to program 2, press “PRG” ↑button. To go back from program 1 to program 2 press the “PRG” ↓button.           

Step 7: Adjust intensity.

After selecting the desired program and setting, you can increase the intensity by pressing the intensity buttons on the key pad.

For outputs C1&C2.

Press the “C1.2”↑button to increase the intensity on outputs C1 and/or C2.

Press the “C1.2” ↓button to decrease the intensity on outputs C1 and/or C2.

For outputs C3&C4.

Press the “C3.4”↑button to increase the intensity on outputs C3 and/or C4.

Press the “C3.4” ↓button to decrease the intensity on outputs C3 and/or C4.

Step 8: Adjust timer.  

Press the “TIMER” button to adjust timer.

Step 9: Turn off the device.

Press the “ON/OFF” button to turn OFF your device.

Step 10: Remove the pads from your skin.

Remove the pads from your skin softly and place them back on the provided pad holder or the protective plastic film.

DO NOT remove the pads before you turn off the device.

Step 11: Take off the pads from wires. Unplug wires from device.